Showing results: 1 - 15 of 85 items found.
-
TD SERIES: AC -
Kusam Electrical Industries Limited
• Dual Aux. Power 110/220V AC• High Accuracy 0.2% RO at 23 °C ± 5 °C• High Dielectric Strength 2.6KV AC / Min,Between Input / Output/ Power Case• ABS Plastic Case, DIN Rail or Wall Mounting
-
NMTU/F -
Metra Blansko a.s.
The NMTU/F device is an AC voltage and frequency transducer with two independent analogous outputs. The A output measures AC voltage, the B output measures the frequency of input voltage. That´s why one single NMTU/F transducer is able to replace two customary transducers, thus making it possible to achieve significant savings in installation space.
-
ACR Systems Inc.
Converts a three phase, 600 VAC, 50/60 Hz power system to three proportional 0 to 5 volt DC outputs.
-
ENVIROMUX-PT3-600 -
Network Technologies Inc
Monitors and reports voltage of any 3 phase circuit. Remotely detect blown fuses or tripped circuit breakers. Three 600 VAC inputs, three 4-20 mA outputs. Inputs and outputs isolated from one another. Frequency: 50/60Hz. Maximum primary current: 600 volts. Accuracy: ±0.25% F.S. @60Hz. Output: 4-20 mA. "Zero" adjustment for accurate 0 VAC reading, and "Calibration" adjustment for frequency and voltage level. Powered by the ENVIROMUX-S420MA-24V. Regulatory approvals: UL, CUL, CE. Requires two ENVIROMUX-S420MA-24V to monitor three phases. Caution: installation should be performed by qualified electricians only. Make sure electrical service is disconnected before making any electrical connections.
-
VT7 AND VT8 Series -
Powertek LLC
The Model VT7 Series dc voltage transducer produces an output which is directly proportional to the input from dc to 10kHz. It functions as a millivolt dc shunt or a high voltage isolator to 1000V
-
VMA -
North Atlantic Industries
NAI’s VMA is a field-adjustable, AC-Powered, AC Voltage Monitor used to monitor voltage characteristics of single- or three-phase power lines. This allows normal operation of system loads when the power-line characteristics are within pre-determined limits.High and low voltage limits, and "pick-up" and "drop-out" time delay are field-adjustable. The VMA voltage monitor is ideally suited for rugged defense and industrial applications.
-
VAA/VQA -
North Atlantic Industries
NAI’s VAA and VQA are AC-Powered, AC Voltage Monitors used to monitor voltage characteristics of single- or three-phase power lines. This allows normal operation of system loads when the power-line characteristics are within pre-determined limits. These voltage monitors are ideally suited for rugged defense and industrial applications.
-
VAD/VQD -
North Atlantic Industries
NAI’s VAD and VQD are DC-Powered, AC Voltage Monitors used to monitor voltage characteristics of single- or three-phase power lines. This allows normal operation of system loads when the power-line characteristics are within pre-determined limits. These voltage monitors are ideally suited for rugged defense and industrial applications.
-
90416 -
HITEC Sensor Solutions Inc.
This miniature, on-board, transducer amplifier is capable of supplying excitation voltage and amplifying millivolt signals from strain gage based transducers.
-
90376 -
HITEC Sensor Solutions Inc.
This miniature, on-board, transducer amplifier is capable of supplying excitation voltage and amplifying millivolt signals from strain gage based transducers.
-
786328-01 -
NI
The RM-26999 is a rack-mounted, signal conditioning device that connects to several simultaneous-sampling multifunction I/O devices for power measurements. It features four voltage input channels with peak voltages up to 2,000 V and four … current transducer ports for current measurements. The current transducer ports are optimized for flux-gate transducers by providing all the power, communication, and signal lines required for accurate measurements.
-
SPS-31 -
Kongter Test & Measurement Co., Limited
SPS-31 is specially designed to test analog and digital DC/AC Voltage meter, Current meter energy meter, DC voltage transducer and Current transducer. It is widely applied for test, production and inspection in research institution, national measurement institution at all levels, and meter manufacturer.
-
-
FUD-I -
Beijing GFUVE Electronics Co.,Ltd.
Single phase current / voltage transducer AC current / voltage transducerAccuracy class can reach 0.2%AC input range can be customized DC output range can be customized
-
CD23/223 -
Validyne Engineering
The CD23 and CD223 Digital Transducer Indicators are designed for use with variable reluctance and differential transformer transducers. The CD23 accepts input from a single transducer, and the CD223 accepts two switch-selectable inputs, with Zero and Span controls for each input. The indicators provide 5 Vrms, 5 kHz carrier excitation voltage to the transducer(s) and solid state circuitry to amplify, demodulate and filter the transducer output signals. A 3 1/2 digit front panel display is standard, with a 4 1/2 digit display optionally available.